Galaxy VM 200 kVA UPS Parallel 400-400 V with Backfeed protection, Start up 5×8

GVMPB200KHS Product picture Schneider Electric

Overview
Presentation
Highly compact, energy efficient 3-phase UPS for data center, facility and industrial applications. to be used with external battery cabinets. Please click here for additional runtime information.
Lead time
Usually Ships within 2 Weeks
General
provided equipment
Built-in modbus protocol adapter
Dust filter
Installation guide
Integrated network management
Seismic compliance
Top and bottom cable entry
bypass voltage tolerance
+/- 10 % settable from +/- 4/6/8 and 10 %
max bypass input current
289 A
bypass current protection
400 A
Number of power module free slots
0
Number of power module filled slots
0
redundant
No
UPS size
WS
Physical
colour
White
depth
85.4 cm
height
197 cm
mounting preference
No preference
net weight
724 kg
mounting mode
Not rack-mountable
two post mountable
0
USB compatible
No
width
105.2 cm
Input
network frequency
40…70 Hz
input voltage limits
250…600 V adjustable
320…456 V 380 V
320…480 V 400 V
320…498 V 415 V
inputvolt_other
380 V
415 V
maximum input current
328 A
switching current capacity
400 A
max short time withstand current
65 kA
input harmonic distortion
Less than 3 % for full load
input protection type
GL fuse
input voltage
400 V 3 phases
inrush current
200 A peak
load power factor
0.5 leading to 0.5 lagging
cos phi
1
Output
rated power in W
180000 W
Maximum configurable power in W
180000 W
harmonic distortion
Less than 2 %
output frequency
50/60 Hz +/- 1 Hz sync to mains
50/60 Hz +/- 1 Hz unsynchronised
outputvolt_other
380 V
415 V
crest factor
Unlimited
UPS type
Double conversion online
Wave type
Sine wave
output connector type
Hard wire 4-wire (3P + E) 1
Hard wire 5-wire (3P + N + E) 1
output voltage tolerance
+/- 1% static and +/- 3% at 100% load step
output harmonic distortion
< 2% linear load and < 3% non-linear load
output overload operation
10 minutes at 125% and 60 seconds at 150%
neutral output current
289 A
bypass type
Built-in static bypass
curve equation
Efficiency
curve fixed loss
0.0067
curve load maximum
100 %
curve load minimum
1 %
curve proportional loss
0.0089
curve square loss
0.0293
curve X-axis maximum
100 %
curve test cond ID
Curve fit to measured efficiency data. All measurements taken in normal operating mode, at typical environmental conditions, with nominal electrical input and balanced PF = 0.9 output.
curve X-axis minimum
0 %
curve X-axis title
Load
curve X-axis units
Percentage
curve Y-axis maximum
100 %
curve Y-axis minimum
50 %
curve Y-axis title
Efficiency
curve Y-axis units
Percentage
graph display
1
output voltage
400 V 3 phases
Maximum configurable power in VA
200000 VA
rated power in VA
200000 VA
Conformance
product certifications
C-Tick
CE
ETL
RCM
standards
EN/IEC 62040-1
EN/IEC 62040-2
EN/IEC 62040-3
IBC 2012 and CBC2013 to Sds=2.02g
ISTA 2B
OSHPD
UL 1778
Environmental
ambient air temperature for operation
0…40 °C
relative humidity
0…95 %
operating altitude
0…3333 ft
ambient air temperature for storage
-25…55 °C
Storage Relative Humidity
0…95 %
storage altitude
0.00…14999.82 m
acoustic level
65 dBA
heat dissipation
24570 Btu/h
show note OP temperature
No
IP degree of protection
IP20
Batteries & Runtime
battery type
External battery system
battery voltage
480 V
discharge battery voltage
384 V
max current discharge
393 A
battery curve
B
Battery power in VAH
0 VAh runtime
extended runtime
0
Communications & Management
free slots
2
control panel
7″ touch screen display
alarm
Audible and visible alarms prioritized by severity
Emergency power off
Yes
Packing Units
Package 1 Weight
770 kg
Package 1 Height
215.6 cm
Package 1 width
149 cm
Package 1 Length
106 cm
Contractual warranty
Warranty
1 year on-site repair or replace with factory authorized Start-Up